; alarmreceiver.conf |
|
; |
|
; Sample configuration file for the Asterisk alarm receiver application. |
|
; |
|
|
|
|
|
[general] |
|
|
|
; |
|
; Specify a timestamp format for the metadata section of the event files |
|
; Default is %a %b %d, %Y @ %H:%M:%S %Z |
|
|
|
timestampformat = %a %b %d, %Y @ %H:%M:%S %Z |
|
|
|
; |
|
; Specify a command to execute when the caller hangs up |
|
; |
|
; Default is none |
|
; |
|
|
|
;eventcmd = yourprogram -yourargs ... |
|
|
|
; |
|
; Specify a spool directory for the event files. This setting is required |
|
; if you want the app to be useful. Event files written to the spool |
|
; directory will be of the template event-XXXXXX, where XXXXXX is a random |
|
; and unique alphanumeric string. |
|
; |
|
; Default is none, and the events will be dropped on the floor. |
|
; |
|
|
|
eventspooldir = /tmp |
|
|
|
; |
|
; The alarmreceiver app can either log the events one-at-a-time to individual |
|
; files in the spool directory, or it can store them until the caller |
|
; disconnects and write them all to one file. |
|
; |
|
; The default setting for logindividualevents is no. |
|
; |
|
|
|
logindividualevents = no |
|
|
|
; |
|
; The timeout for receiving the first DTMF digit is adjustable from 1000 msec. |
|
; to 10000 msec. The default is 2000 msec. Note: if you wish to test the |
|
; receiver by entering digits manually, set this to a reasonable time out |
|
; like 10000 milliseconds. |
|
|
|
fdtimeout = 2000 |
|
|
|
; |
|
; The timeout for receiving subsequent DTMF digits is adjustable from |
|
; 110 msec. to 4000 msec. The default is 200 msec. Note: if you wish to test |
|
; the receiver by entering digits manually, set this to a reasonable time out |
|
; like 4000 milliseconds. |
|
; |
|
|
|
sdtimeout = 200 |
|
|
|
; |
|
; Wait for the connection to settle post-answer. Adjustable from 500 msec. to 10000 msec. |
|
; The default is 1250 msec. |
|
; |
|
|
|
answait = 1250 |
|
|
|
; When logging individual events it may be desirable to skip grouping of metadata |
|
|
|
;no_group_meta = yes |
|
|
|
; |
|
; The loudness of the ACK and Kissoff tones is adjustable from 100 to 8192. |
|
; The default is 8192. This shouldn't need to be messed with, but is included |
|
; just in case there are problems with signal levels. |
|
; |
|
|
|
loudness = 8192 |
|
|
|
; |
|
; The db-family setting allows the user to capture statistics on the number of |
|
; calls, and the errors the alarm receiver sees. The default is for no |
|
; db-family name to be defined and the database logging to be turned off. |
|
; |
|
|
|
;db-family = yourfamily: |
|
|
|
; |
|